Products Description
HIMA F332216 Digital Output Module

Technical Specifications
Model:F332216
Brand:HIMA
Safety certification:SIL3,IEC61508,TÜV certified
Channel:16-channel safety digital output
Output signal:24V DC,0.5A per channel
Diagnosis:Short circuit,overload and load fault monitoring
Mounting:Plug-in subrack installation,4TE width
Protection class:IP20
Power supply:24V DC ±15%
Operating temperature:-20~+60℃
Relative humidity:5~95% non-condensing
Weight:0.42kg
Certification:CE
System compatibility
Special variant version of F3322,designed for HIMA HIQuad H41q / H51q safety system,output safety control signals for field solenoid valves,alarm relays and safety actuators,widely used in petrochemical,chemical plant ESD emergency shutdown and F&G fire gas protection system.
Function
SIL3 16-channel safety digital output module.It receives safety logic command from HIQuad CPU,outputs 24V DC control signal to field safety equipment,supports continuous loop diagnosis for short circuit and overload.When safety trip triggered,module will cut off output to realize fail-safe protection.
Installation
Plug into HIQuad H41q/H51q rack backplane,wire field actuators to module terminals,complete hardware configuration via ELOPII engineering software.
Interface
‑16 channels digital output terminals
‑Backplane bus connector for power and data exchange
‑LED indicators for channel status and fault
Circuit feature
1oo2 fail-safe safety architecture,periodic hardware self-test,built-in overcurrent protection,strong anti-electromagnetic interference,meets SIL3 functional safety requirements for hazardous industrial environment.
Feature
HIQuad series special variant 16-channel SIL3 24V DC digital output module F332216. Common faults:output channel burnout,overcurrent damage,connector pin failure.Confirm H41q/H51q rack firmware version before replacement.
Diagnostic
Module or wiring fault triggers channel fault alarm;controller executes safety interlock logic.
Built‑in function
F332216 outputs safety control signals for SIS safety instrumented system emergency shutdown and fire protection interlock,widely used for chemical and power plant safety spare replacement.
Product Brief
F332216 belongs to HIMA HIQuad I/O family,plug-in 16-channel SIL3 digital output module (special variant of F3322) for H41q/H51q safety subrack. Verify rack compatibility before ordering. Test output performance and fault diagnosis function during commissioning. ESD anti‑static protection shall be followed during installation.